Q4. a) Why is a synchronous motor not self-starting? What are the various ways in which it can be started? (6)
b) A coil has a resistance of 4 ohms and an inductance of 0.00954 henry. Calculate the power the coil will absorb and its power factor when it is connected to a 100-volts 50-cycle supply. (10)
Q7. a) Explain what do you understand by the term ‘transducer’? (6)
b) A coil of resistance 10 ohms and inductance 100mH is connected in series with two parallel capacitors each of value 100 mF across a 250 V, 50Hz supply. determine (10)
i) The circuit current
ii) The total power factor
iii) The power taken from the supply.
Q6. A 100 KVA, 2400/240 V, 50 Hz, 1-phase transformer has no- load current of 0.64 A and a core loss of 700 W, when its high voltage side is energized at rated voltage and frequency . calculate the two components of no-load current. If this transformer supplies a load current of 40 amp at 0.8 lagging power factor at its low voltage side, determine the primary current and its power factor. Ignore leakage impedance drop. (16)
Q6.a) Derive an expression for the emf induced in an a.c. generator. (6)
b) A 3000 KVA, 6-pole alternator runs at 1000 r.p.m. in parallel with other machines on 3300V bus-bars. The synchronous reactance is 25%. Calculate the synchronizing power for one mechanical degree of displacement and the corresponding synchronizing torque. (10)