Q1.a) Explain three methods of overcurrent protection for electrical circuit. (8)
b) Explain with aid of diagram, the meaning of the term inverse current time characteristic (8)
Q6. A 100 KVA, 2400/240 V, 50 Hz, 1-phase transformer has no- load current of 0.64 A and a core loss of 700 W, when its high voltage side is energized at rated voltage and frequency . calculate the two components of no-load current. If this transformer supplies a load current of 40 amp at 0.8 lagging power factor at its low voltage side, determine the primary current and its power factor. Ignore leakage impedance drop. (16)
Q8. With reference to entry into enclosed spaces onboard: a) Define “Enclosed space” and give example of enclosed spaces onboard (6) b) Describe the checks done for testing the atmosphere inside such enclosed spaces. (5)
c) Explain safety precautions taken prior to entry into enclosed spaces onboard vessel. (5)
Q8.a) CO2 is to be released in engine room in case of fire. Briefly describe steps taken before it can be released.
b) What means are provided to prevent inadvertent release of CO2 in engine room?
Q9. With respect to the hazardous areas of tankers. (a) Explain the term flameproof (Ex d) for electrical equipment. (6) (b) State the type of electrical equipment that would be protected in this way. (5) (c) List likely defects of flameproof equipment. (5)