Q6. With reference to the circuit breaker for an a.c. generator A. Describe the preventive maintenance carried out on the circuit breaker for an A.C Generator. B. Explain the sequence of events that might occur if the breaker opens on a short circuit and state the check you would require following such event. C. Give a safe procedure to follow should a main circuit breaker fail to open under fault condition.
Q6. You have opened up a main sea-water circulating pump (centrifugal type) onboard your vessel for examination and overhaul, describe the checks you would make, and state your conclusion regarding any faults found.
Q4. With reference to Auxiliary boiler safety valves;
A. Describe with the aid of Sketch the safety valve for an auxiliary boiler;
B. Identify with reasons. The parts that require particularly close attention during overhaul;
C. Describe how the safety valves are reset after an overhaul.