Q2. With Respect to Insulated and Earthed Neutral Systems used on board:
a) Discuss the Advantages and Disadvantages of both Insulated and Earthed Systems used on board. (8)
b) Discuss the consequences of earth fault in an earthed distribution system. (4)
c) What would be the Ohmic value of the NER to limit the earth fault to the full load rating of a 2 MW, 0.8 pf, 3.3KV, 3Phase A.C. generator? (4)
Q4.a) Explain the construction and principle of operation of permanent magnet moving coil instrument. (8)
b) A permanent magnet moving coil instrument has a coil of dimension 15 mm × 12mm. The flux density in the air gap is 1.8 × 10-3 wb/m2 and the spring constant is 0.4 × 10-6 Nm / rad. Determine the number of turns required to produce an angular deflection of 900 when a current of 5 mA is flowing through the coil. (8)
Q5. A 400V, 4-pole, 50 Hz, 3-phase, 10 hp, star connected induction motor has a no load slip of 1% and full load slip of 4%, find the following:
(i) Syn speed
(ii) No -load speed
(iii) Full load speed
(iv) Frequency of rotor current at full load
(v) Full – load torque (16)
Q6. With reference to Diesel engine driven alternator:
a) Explain the significance of the term “speed droop” during the parallel operation of alternators. Assuming two alternators are running in parallel, outline the frequency vs load characteristics of the alternators while load sharing. (8)
b) Two 3Ø alternators operate in parallel, the rating of A is 1000 kW and B is 800 kW. The droop setting of each generator is 4%, If the load to be shared by both the generators is 1000 kw, calculate the load sharing by generators A and B, if the original frequency at no-load is 62Hz. (8)
Username or email address *Required
Password *Required
Note: Entering wrong username in the login form will ban your IP address immediately. Entering wrong password multiple times will also ban your IP address temporarily.
Log in
Lost your password? Remember me
No account yet?