Q1. (a) Explain at least three features which assist in the starting of lifeboat engines in cold climate conditions.
(b) Describe TWO devices that control the rate of fall of a lifeboat when launched from standard davits
(C) With reference to Resolution MSC 402(96) and M.S. Notice 1 of 2020 on life boats, rescue boats, launching appliances and release gear; state who are authorized /allowed to carry out following routine jobs:
(i) Weekly and monthly inspections and routine maintenance
(ii) Annual thorough examinations and operational tests
(iii) Five-year thorough examination, overhaul, overload operational tests and repair.
Q2. With reference to lifeboats, describe with the aid of sketches: i. The handbrake used for lowering and state how it may be tested; ii. The centrifugal brake and state the method of testing; iii. Lifeboat servicing requirement and intervals for life boat wire fall renewal as per SOLAS 74. iv. The handbrake used for lowering
Q7. With reference to automatic sprinkler system for firefighting purposes:
a) Explain, with the aid of a heat release versus time diagram, the difference between fire control and fire suppression. (6)
b) State the limitations of using glass bulb to activate sprinkler heads and suggest, with reasons, an alternative mechanism. (4)
c) The safety devices incorporated in the system. (3)
d) The parameters governing the volume of the pressure tank. (3)
Username or email address *Required
Password *Required
Note: Entering wrong username in the login form will ban your IP address immediately. Entering wrong password multiple times will also ban your IP address temporarily.
Log in
Lost your password? Remember me
No account yet?
DieselShip support
Send us a message and we'll reply by email, usually within one business day.
We've logged your ticket and sent a confirmation to your email.