Q1. A. Discuss the care maintenance required especially for the stator and rotor of an A.C. generator. (8)
B. Explain what is likely to occur if the driving power of one A.C. generator suddenly fail when two generators are running in parallel. What safety devices are usually provided as safeguards against such events. (8)
--- PREVIOUSLY ASKED AS ---
Q3. A. Give a brief outline of the care maintenance that should be given to the stator and rotor of an A.C. generator.
B. Explain what is likely to occur if the driving power of one A.C. generator suddenly fails when two generators are running in parallel. What safety devices are usually provided for such events?
Q2. Compare methods of obtaining speed regulation of three-phase induction motors generally used in tankers by means of:
A. Rotor resistance.
B. Cascade system.
C. Pole-changing.
Give examples where each system may be employed with advantage. (16)
Q3. A. Explain how the efficiency and regulation of a transformer can be assessed by open circuit and short circuit tests? (10)
B. What is meant by equivalent resistance? (6)
Q4. With reference to the condition monitoring of electrical machinery:
A. State TWO important parameters that may be recorded. (8)
B. Explain how the parameters are measured and what defects may be revealed. (8)
Q5. A. (i) Discuss the various hazards and problems which are associated with electric cable insulation in the event of fire.
(ii) Suggest remedies for these problems. (8)
B. State how the spread of fire may be reduced by the method used for installing electric cables. (8)
Q6. A. Describe the effect of the following loads on power factor: -
(i) Induction motors.
(ii) Transformers.
(iii) Partly loaded motors.
(iv) Cage type motors. (6)
B. In a 50-KVA, star-connected, 440-V, 3-phase, 50-Hz alternator, the effective armature resistance is 0.25 ohm per phase. The synchronous reactance is 3.2 ohm per phase and leakage reactance is 0.5 ohm per phase. Determine at rated load and unity power factor.
(a) Internal e.m.f Ea
(b) no-load e.m.f E0
(c) percentage regulation on full-load
(d) value of synchronous reactance which replaces armature reaction. (10)
Q9. (a) What is leakage flux as it applies to the iron-core transformer? How is it taken into account in the analysis of the transformer? (6)
(b) The low-voltage release of an A.C. motor-starter consists of a solenoid into which an iron plunger is drawn against a spring. The resistance of the solenoid is 35 ohms. When connected to a 220 V, 50 Hz, A.C. supply the current taken is at first 2 A, and when the plunger is drawn into the “full-in” position the current falls to 0.7 A. Calculate the inductance of the solenoid for both positions of the plunger and the maximum value of flux-linkages in weber-turns for the “full-in” position of the plunger. (10)
Username or email address *Required
Password *Required
Note: Entering wrong username in the login form will ban your IP address immediately. Entering wrong password multiple times will also ban your IP address temporarily.
Log in
Lost your password? Remember me
No account yet?
DieselShip support
Send us a message and we'll reply by email, usually within one business day.
We've logged your ticket and sent a confirmation to your email.